Tag 'operator = 50Hertz Transmission GmbH'
Ergebnisse: 43
- {addr:country=DE, addr:postcode=10247, building=electricity, operator=50Hertz Transmission GmbH, addr:city=Berlin, frequency=50, voltage=380000, addr:suburb=Prenzlauer Berg, addr:housenumber=65, addr:inclusion=actual, location=indoor, short_name=UW FRH9, addr:street=Eldenaer Straße, gas_insulated=yes, power=switchgear}
- 380-kV-Transversale Berlin
- {ref=402a;402b, location=underground, power=cable, layer=-1, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- 380-kV-Transversale Berlin
- {cables=3, line=busbar, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, ref=903, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, fixme=Leitungsnummer, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- {cables=3, line=bay, location=underground, power=cable, layer=-1, operator=50Hertz Transmission GmbH, frequency=50, voltage=220000}
- {addr:housename=MI9, addr:country=DE, roof:shape=flat, building:levels=1, addr:postcode=10785, building=industrial, operator=50Hertz Transmission GmbH, addr:city=Berlin, frequency=50, voltage=380000;110000, addr:suburb=Tiergarten, addr:housenumber=8, location=indoor, addr:street=Bissingzeile, gas_insulated=yes, power=switchgear}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=220000}
- Berlin/Friedrichshain
- Berlin/Mitte
- Berlin/Friedrichshain
- {cables=3, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- {cables=3, ref=517, line=bay, power=line, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- Umspannwerk Gransee
- {wires=triple, cables=3, ref=518, line=bay, power=line, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- 380-kV-Transversale Berlin
- {cables=3, fixme=Leitungsnummer, line=bay, location=indoor, gas_insulated=yes, power=cable, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- 380-kV-Transversale Berlin
- {wires=triple, cables=3, ref=518, power=line, operator=50Hertz Transmission GmbH, frequency=50, voltage=380000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=220000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=220000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=380000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=380000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=220000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=disconnector, voltage=220000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=380000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=380000}
- {cables=3, location=outdoor, power=switch, operator=50Hertz Transmission GmbH, frequency=50, switch=circuit_breaker, voltage=380000}
Quelle / Ursprung dieser Information: OpenStreetmap